PM400K5
Digital Console with Thermal Sensor
PM130D
Digital Console with Slim Photodiode Sensor
PM120VA
Analog Console with Photodiode Sensor
Power Meter Kit Specifications | ||||
---|---|---|---|---|
Item # | Power Range | Wavelength Range | Sensor Type | Console Type |
PM120VA | 50 nW - 50 mW | 200 - 1100 nm | Si (S120VC) | Analog (PM100A) |
PM120D | 50 nW - 50 mW | 400 - 1100 nm | Si (S120C) | Digital (PM100D) |
PM400K1 | 50 nW - 50 mW | 400 - 1100 nm | Si (S120C) | Touchscreen Digital (PM400) |
PM121D | 500 nW - 500 mW | 400 - 1100 nm | Si (S121C) | Digital (PM100D) |
PM400K2 | 500 nW - 500 mW | 400 - 1100 nm | Si (S121C) | Touchscreen Digital (PM400) |
PM130D | 500 pW - 500 mWa | 400 - 1100 nm | Slim Si (S130C) | Digital (PM100D) |
PM400K3 | 500 pW - 500 mWa | 400 - 1100 nm | Slim Si (S130C) | Touchscreen Digital (PM400) |
PM122D | 50 nW - 40 mW | 700 - 1800 nm | Ge (S122C) | Digital (PM100D) |
PM400K4 | 50 nW - 40 mW | 700 - 1800 nm | Ge (S122C) | Touchscreen Digital (PM400) |
PM125D | 2 mW - 10 W | 0.19 - 20 µm | Thermal (S425C) | Digital (PM100D) |
PM400K5 | 2 mW - 10 W | 0.19 - 20 µm | Thermal (S425C) | Touchscreen Digital (PM400) |
Power Meter Selection Guide |
---|
Sensors |
Photodiode Power Sensors |
Thermal Power Sensors |
Thermal Position & Power Sensors |
Pyroelectric Energy Sensors |
Power Meter Consoles and Interfaces |
Digital Handheld Console |
Analog Handheld Console |
Touchscreen Handheld Console |
Dual-Channel Benchtop Console |
USB Interfaces with External Readout |
Complete Power Meters |
Power Meter Bundles |
Wireless Power Meters with Sensors |
Compact USB Power Meters |
Field Power Meters for Terminated Fibers |
Our optical power meter kits consist of a console, a C-series photodiode or thermal power sensor, and a post mounting assembly. Except for the PM120VA, which includes the PM100A analog power meter console, the sensor in each kit is paired with either a PM100D digital or PM400 touchscreen digital power meter console. For a full list of available kits, see the table to the right.
All three consoles have a USB 2.0 connection that allows them to be controlled remotely using a PC with the Optical Power Meter software package installed (see the Software tab for details).
PM100A Analog Console
Suitable for both absolute and relative power measurements, the PM100A analog power meter console features an analog needle display and a supplemental LCD screen. The analog needle is ideal for relative power measurements and for watching small power fluctuations. The PM100A is compatible with all C-Series photodiode sensors and thermal sensors; it is not compatible with our pyroelectric energy sensors. The PM120VA power meter kit includes the PM100A console and power cables, an S120VC sensor, and a USB flash drive with the software package preloaded. For more information on the PM100A analog console features, see the Specs and Display tabs above or visit the full web presentation.
PM100D Digital Console
The PM100D digital power and energy meter console features a menu-driven control panel, 4" backlit display, and SD card slot for storing data. Measurements screens include a numeric readout useful for standard power and energy readings, a simulated analog needle, graphs of power measurements over time, and a statistics view. Additionally, the PM100D console has a tuning mode that provides audio feedback for use when the detector is not within visual range. See the PM100D Display tab for more information. The console is compatible with all our C-Series sensors for power or energy measurements, including our pyroelectric energy sensors, and includes a USB flash drive with the software package preloaded. For more information on the PM100D digital console features, see the Specs and Display tabs above or visit the full web presentation.
PM400 Touchscreen Digital Console
The PM400 touchscreen digital power and energy meter console features a 4.3" display with multi-touch technology. Capacitive buttons on the front of the unit enable fast access to set the source wavelength or spectrum, a delta mode that shows the change in power from a user-selected set point, the zeroing function, and device main menu. In addition to pre-programming source wavelengths or spectra for calibrating measurements, users can enter and save up to twelve attenuation values or data files to correct for effects that external devices (such as filters or beamsplitters) may have on the power measurement.
A 14-pin auxiliary input allows users to connect their own humidity and temperature sensors as well as access four programmable I/O ports for controlling shutters, interlock devices, laser warning lights, and other common lab devices (see the Pin Diagrams tab for pin descriptions). Alternatively, a 2.5 mm stereo (3P) jack accepts the TSP-TH thermistor temperature probe. Like the PM100D, this console is compatible with all our C-Series sensors. For more information on the PM400 touchscreen digital console features, see the Specs and Display tabs above or visit the full web presentation.
Additional Power Meter and Sensor Options
The power meter consoles and sensors in these kits can also be purchased individually. Additionally, Thorlabs offers self-contained wireless power meters, designed for both handheld operation and remote control via Bluetooth or USB, and compact USB power meters, designed to be operated via software control on a PC.
Recalibration Service
Recalibration services are available for our photodiode and thermal power meter sensors and consoles. We recommend recalibrating your Thorlabs sensor and console as a pair; however, each may be recalibrated individually. To order this service for your sensor or console, scroll to the bottom of the page and select the appropriate Item # that corresponds to your sensor or console. Recalibration of a single-channel console is included with the recalibration of a sensor at no additional cost.
Click here for the complete PM100A product presentation.
PM100A Specifications | |
---|---|
Photodiode Sensor Input (Current) | |
Measurement Ranges | 6 Decades; 50 nA - 5 mA |
Units | W |
Accuracy | ±0.2% of Full Scale (5 µA - 5 mA) ±0.5% of Full Scale (50 nA) ±3% Full Scale Analog Meter |
Bandwidth | DC to 100 kHz, Dependent on Sensor and Settings |
Analog Output | |
Connector | SMA |
Voltage Range | 0 - 2 V |
Bandwidth | Up to 100 kHz, Dependent on Sensor and Settings |
Accuracy | ±3% |
General | |
Sensor Input | Female DB9 for C-Series Connectors |
Display | Analog Needle with 132 x 32 pixel LCD Readout |
Display Update Rate | 20 Hz |
Display Screens | Numerical, Relative Measurements, Tuning, Statistics, Mechanical Analog Needle |
Memory Card | N/A |
A/D Converter | 16 bit |
Computer Connectivity | USB 2.0, Mini USB |
Battery | Li-Polymer 3.7 V, 1300 mAh; up to 8 hrs of Operation |
Dimensions | 7.2" x 4.3" x 1.6" (183 mm x 109 mm x 40 mm) |
Operating / Storage Temp | 0 to 40 °C / -40 to 70 °C |
Mounting | Kickstand, 1/4"-20 Mounting Hole |
Click here for the complete PM100D product presentation.
PM100D Specifications | |
---|---|
Photodiode Sensor Input (Current) | |
Measurement Ranges | 6 Decades; 50 nA - 5 mA |
Units | W, dBm, W/cm2, A |
Accuracy | ±0.2% of Full Scale (5 µA - 5 mA) ±0.5% of Full Scale (50 - 500 nA) |
Bandwidth | DC to 100 kHz, Dependent on Sensor and Settings |
Thermopile Sensor Input (Voltage) | |
Measurement Ranges | 4 Decades; 1 mV - 1 V |
Units | W, dBm, W/cm2, V |
Accuracy | ±0.5% of Full Scale (10 mV - 1 V) ±1% of Full Scale (1 mV) |
Bandwidth | DC to 10 Hz, Dependent on Sensor and Settings |
Time Constant Correction | 1 - 30 s |
Analog Output | |
Connector | SMA |
Voltage Range | 0 - 2 V |
Bandwidth | Up to 100 kHz, Dependent on Sensor and Settings |
Accuracy | ±3% |
General | |
Sensor Input | Female DB9 for C-Series Connectors |
Display | 3.2" x 2.4" (81.4 mm x 61 mm), 320 x 240 pixels |
Display Update Rate | 20 Hz |
Display Screens | Numerical, Bar Graph, Trend Graph, Statistics, Simulated Analog Needle |
Memory Card | SD, 1 GB |
A/D Converter | 16 bit |
Computer Connectivity | USB 2.0, Mini USB |
Battery | Li-Polymer 3.7 V, 1300 mAh; up to 8 hrs of Operation |
Dimensions | 7.2" x 4.3" x 1.6" (183 mm x 109 mm x 40 mm) |
Operating / Storage Temp | 0 to 40 °C / -40 to 70 °C |
Mounting | Kickstand, 1/4"-20 Mounting Hole |
Click here for the complete PM400 product presentation.
Specifications | |
---|---|
Compatible Detectors | Thorlabs' C-Series Photodiode, Thermal, and Pyroelectric Sensors Photodiodes up to 5 mA, Thermopiles up to 1 V, and Pyroelectric Detectors up to 100 V |
Display | |
Type | 4.3" TFT, WQVGA, 400 x 272 Pixels, 16 Bit Color |
Viewing Area | 95 mm x 54 mm |
Update Rate (Max) | 10 Hz Numerical, 25 Hz Analog Simulation |
Format | Numerical, Bar Graph, Trend Graph, Statistics, and Simulated Analog Needle |
Backlight | LED, Adjustable |
Features | Projected Capacitive Touchscreen and Buttons, Support Stand, Rubberized Outside, 2 x M3 Threaded Inserts for Mounting on Back Side |
Analog Output | |
Connector | 3.5 mm Mono Audio (2P) Jack, Adapter to BNC Included |
Signal | Amplified Input Signal - Not Corrected |
Voltage Range | 0 to 2 V |
Accuracy | ±3% |
Bandwidth | Up to 100 kHz, Dependent on Sensor and Settings |
Auxiliary Input/Output | |
Connector | 2 x 7 Pins, 0.1" Socket, Top Side |
Function | 4 x GPIO 2 x 10 bit ADC for External Temperature, Relative Humidity Sensor +3.3 V, +/- 2.5 V (100 mA Max) |
Temperature Sensor Internal to C-Series Optical Sensora | |
Temperature Sensor Type | Thermistor |
Temperature Measurement Range | -10 °C to 80 °C |
External Temperature Sensor | |
Supported Temperature Sensor | Thermistor NTC 0.1 - 100 kΩ, B-Value 1000 - 9999 K |
Temperature Measurement Range | -10 °C to 80 °C (with TSP-TH) |
Connector | 2.5 mm Stereo Audio (3P) Jack |
Sound | |
Type | Internal Speaker |
Function | Laser Tuning Support, Console Function Support |
Memory | |
Type | NAND Flash |
Size | 4 GB |
Interfaces | |
Type | USB 2.0 |
Connector | Mini-B USB |
Power Management | |
Battery | LiPo 3.7 V 2600 mAh |
Charger | Built In; Charging Current: 0.5 / 1 A |
Power Connector | Mini USB |
General | |
Operating Temperature Rangeb | 0 to 40 °C |
Storage Temperature Range | -40 to 70 °C |
Dimensions | 136 mm x 96 mm x 29 mm |
Weight | 0.35 kg |
PM100A Display | |
---|---|
Standard Absolute Measurements | Relative Measurements |
This display shows the current absolute power values on both the mechanical needle and the LCD display. | Shows positive or negative power deviation from an initially zeroed position (needle in middle position). The offset and the absolute power value will be displayed in two sub displays in negative presentation. |
Power Tuning with Sound Support | Statistics Screen |
This display shows the maximum reached power level. The level can be reset to the actual power level. |
A display showing the current, min, max, and average power. All items can be reset to restart data sampling. |
Wavelength Setting | |
Configuration screen to set the wavelength of the incident beam. Easy switching between 9 user preconfigurable wavelengths. |
PM100D Display | |||
---|---|---|---|
Numeric Screen (Power Mode) | Numeric Screen (Energy Mode) | ||
This display combines a clear, numerical 4-digit read out of the optical power, a bar graph function with zooming capabilities, and configurable sub displays. | A display with the same option as on the left for optical energy read outs. | ||
Trend Graph (Power Mode) | Needle Tuning (Power Mode) | ||
For laser tuning and beam alignment to visualize changes and trends together with an additional 4-digit numerical value of the absolute power. | A display imitating an analog needle together with an additional 4-digit numerical value for laser tuning tasks. A special feature is a resettable max hold indicator and a shiftable tuning sound. | ||
Pulse Chart (Energy Mode) | Statistics Screen (Power Mode) | ||
Like the Trend Graph (Power Mode), this shows changes and trends together with an additional 4-digit numerical value of the absolute energy of incident beam pulses. | The statistics display shows the actual, minimum, maximum and mean value in linear and logarithmic representation; further the standard deviation, the max/min ratio, the number of samples and the elapsed time. |
Thorlabs' PM400 Power Meter Console features a front panel with several key elements, as shown in the photo to the right. The projected capacitive touchscreen and buttons are sensitive enough to allow smooth operation even when the user wears cotton, latex, or nitrile gloves, but durable enough to be cleaned with standard screen cleaning solvents.
Additional Features
In addition to allowing users to select different measurement modes and settings, the PM400 incorporates other features to allow users to customize the interface.
The screenshots below provide an overview of some of the measurement views, measurement settings, functions, and calculators accessible through the touchscreen display.
Subpanel Display Options | ||
---|---|---|
Photodiode Sensors | Thermal Sensors | Pyroelectric Sensors |
Current (IDET) | Voltage (VDET) | Voltage (VDET) |
Power (Φe) | Power (Φe) | Energy (WDET) |
Power in dBm (Φe) | Power in dBm (Φe) | N/A |
Max | Max | Max |
Min | Min | Min |
Ratio (Max/Min) | Ratio (Max/Min) | Ratio (Max/Min) |
Sensor Temperaturea | Sensor Temperaturea | N/A |
Frequency | Frequency | Frequency |
External NTC Temperature | External NTC Temperature | External NTC Temperature |
Irradiance (Ee) | Irradiance (Ee) | Fluence (He) |
The numerical display shows a digital measurement of the power or energy with a bar graph along the bottom. The orange and blue triangles on the bar graph show the min and max values detected during the measurement. To reset the min and max values, press the reset button on the front panel. The six rectangular subpanels immediately above the power or energy measurement are configurable displays, allowing the user to select which parameters to view. The Subpanel Display Options table provides a summary of available settings for each style of detector.
Measurements can be viewed with a simulated analog needle. The orange and blue marks are indicators for the max and min measured power, and the scale can be zoomed by a factor of 10. Icons down the side of the screen allow the user to set the bandwidth, adjust the resolution of the digital value at the bottom of the display, change units, adjust the display update rate or change screens.
In the graph view, the user can monitor the optical power or energy of a source as it changes over time. A second, optional display can be added that shows the readout from a connected temperature sensor (the upper graph in the screenshot above). Icons on the side of the window allow the user to start and stop the measurement, scroll through the data, and open the folder where the measurement is saved.
In the statistics display, the user can start a sequential measurement. The sample rate and duration can be adjusted from the Capture Settings screen, accessible from the main menu. The bottom bar of the display shows the number of measurements taken, total elapsed time since the measurements were started, and the measurement interval. The main part of the display shows statistics for the accumulated measurements, including the minimum, maximum, mean, and standard deviation.
This mode can be entered by pressing the λ symbol on the front panel. The unit can store up to 12 preset spectral correction entries, editable by the user. In their simplest form, these entries can consist of a single user-entered wavelength that will be used in conjunction with the NIST-traceable calibration data from a Thorlabs' sensor to produce a calibrated power measurement. Alternatively, each entry can be a .csv file with the source spectrum that has been uploaded and saved. When a spectral correction entry is selected, the entry name will be displayed in the field above the spectral correction button.
External devices within a setup, such as a filter or beamsplitter, may be needed to attenuate the signal being measured. The attenuation correction function allows the PM400 to display a power reading that accounts for these sources of attenuation. Attenuation values can be assigned as a multiplier (e.g. x2), in percent, in dB, or in OD (optical density). Alternatively, complete filter transmission curves can be uploaded and saved. Up to 12 different attenuation settings can be programmed and stored.
The PM400 main menu allows access to device features including the screen brightness, the menus to set the parameters for power, energy, and temperature measurements, a screen for calculating laser pulse characteristics, and a unit converter.
This screen allows the user to set the parameters for taking data. User-selectable settings include manual or automatic data acquisition, the exposure time, the number of samples, and the capture interval. It also allows the temperature logging parameters to be set. Once all of the settings are selected, this screen will return an estimated file size so that the user can ensure there is enough free memory on the device. In the case of manual operation (the user manually starts and stops the measurement), the estimated output file size will be the rate at which memory is used up as the data is collected.
This screen allows the user to view sensor-dependent content, adjust common settings such as wavelength, attenuation, mode, etc., and enter beam parameters.
If an external temperature sensor is hooked up to the PM400, the user can adjust the parameters here.
The PM400 has several calculators. The laser calculator screen allows the user to calculate laser beam parameters based on available inputs. A unit converter provides quick conversions between Watts and dBm or between wavelength, frequency, wavenumbers, and photon energy.
Connection | ||
---|---|---|
Pin | PM100A | PM100D |
1 | +5 V (100 mA Max Current from This Pin) | |
2 | DO NOT USEa | |
3 | AGND (Analog Ground): Photodiode Ground (Anode), Thermal and Pyroelectric Sensor Ground |
|
4 | Photodiode Cathode | |
5 | Not Connected | Pyro-Electric Sensor + |
6 | DGND (Digital Ground) | |
7 | Present: Connect this Pin via a 1 kΩ to 10 kΩ Resistor to Pin 3 (AGND) to Enable a Custom Sensor |
|
8 | Thermal Sensor + | |
9 | Not Connected |
0 ... 2 V,
SMA Female
Pin | Connection |
---|---|
1 | +5 V (100 mA Max Current from This Pin) |
2 | DO NOT USEa |
3 | AGND (Analog Ground): Photodiode Ground (Anode), Thermal and Pyroelectric Sensor Ground |
4 | Photodiode Cathode |
5 | Pyroelectric Sensor + |
6 | DGND (Digital Ground) |
7 | Present: Connect this Pin via a 1 kΩ to 10 kΩ Resistor to Pin 3 (AGND) to Enable a Custom Sensor |
8 | Thermal Sensor + |
9 | Not Connected |
Pin | Connection |
---|---|
1 | Ground |
2 | +3.3 VDC, 0.1 A |
3 | Do Not Use (No Function) |
4 | ADC Current In (Humidity Sensor) |
5 | Temp / Humidity Detection Module |
6 | ADC Current In (Temperature Sensor) |
7 | GPIO 02 |
8 | GPIO 01 |
9 | GPIO 03 |
10 | GPIO 04 |
11 | Ground |
12 | + 2.5 VDC, 0.05 A |
13 | Ground |
14 | -2.5 VDC, 0.05 A |
The Optical Power Monitor GUI software features power measurement, readout from up to eight power meters, and remote wireless operation.
For details on specific software features, please see the user manual.
Users interested in the legacy Power Meter Software can find it by visiting the software page.
The PM101 Series Power Meters are only compatible with version 2.0 or later. The PM102 Series Power Meters are only compatible with version 2.1 or later. The PM103 Series Power and Energy Meters are only compatible with version 3.0 or later. The PM5020 Console is only compatible with version 4.0 or later. The PM60 and PM61 Power Meter Series are only compatible with version 6.0 or later.
The Optical Power Monitor software GUI enables seamless control of up to eight power meters that are connected via USB, RS232, or Bluetooth® wireless technologya. The latest software, firmware, drivers, and utilities for these power meters can be downloaded here.
Multiple data measurement and analysis functions are integrated into the GUI package. The interface offers a user-friendly design with minimal use of color and low brightness that is ideal use in dark lab environments while wearing laser safety glasses. Measured data can be displayed in real time as a simulated analog needle, digital values, line graph, or bar graph. Continuously logged and short-term measurements can be recorded for data viewing and analysis at a later point. A built-in statistics mode analyzes measured data and continuously updates to reflect new measurements within the pre-determined measurement period. Beam position measurements are also supported when used with our thermal position & power sensors.
The Optical Power Monitor software package installs the GUI, which then can be used to control the touchscreen, handheld, or USB-interface power meters. Firmware updates for supported power meters are also available. Programming examples and drivers for interfacing with our power and energy meter consoles using LabVIEW, C/C++, Visual C#, and Python are installed with the software; refer to the manual for details.
Please note that the Optical Power Monitor Software uses different drivers than the Power Meter Utilities Software and Thorlabs recommends using the new driver TLPM.dll. For users who wish to use the legacy Power Meter Software or use custom software designed using the older PM100D.dll driver, a Power Meter Driver Switcher program is included for easy swapping of the installed driver between the two versions.
a. The PM61 Series, PM160, PM160T, and PM160T-HP power meters are equipped with Bluetooth® connections.
Determining whether emission from a pulsed laser is compatible with a device or application can require referencing parameters that are not supplied by the laser's manufacturer. When this is the case, the necessary parameters can typically be calculated from the available information. Calculating peak pulse power, average power, pulse energy, and related parameters can be necessary to achieve desired outcomes including:
Pulsed laser radiation parameters are illustrated in Figure 1 and described in the table. For quick reference, a list of equations is provided below. The document available for download provides this information, as well as an introduction to pulsed laser emission, an overview of relationships among the different parameters, and guidance for applying the calculations.
Equations: |
||||
and | ||||
Peak power and average power calculated from each other: |
||||
and | ||||
Peak power calculated from average power and duty cycle*: | ||||
*Duty cycle () is the fraction of time during which there is laser pulse emission. |
Figure 1: Parameters used to describe pulsed laser emission are indicated in the plot (above) and described in the table (below). Pulse energy (E) is the shaded area under the pulse curve. Pulse energy is, equivalently, the area of the diagonally hashed region.
Parameter | Symbol | Units | Description | ||
---|---|---|---|---|---|
Pulse Energy | E | Joules [J] | A measure of one pulse's total emission, which is the only light emitted by the laser over the entire period. The pulse energy equals the shaded area, which is equivalent to the area covered by diagonal hash marks. | ||
Period | Δt | Seconds [s] | The amount of time between the start of one pulse and the start of the next. | ||
Average Power | Pavg | Watts [W] | The height on the optical power axis, if the energy emitted by the pulse were uniformly spread over the entire period. | ||
Instantaneous Power | P | Watts [W] | The optical power at a single, specific point in time. | ||
Peak Power | Ppeak | Watts [W] | The maximum instantaneous optical power output by the laser. | ||
Pulse Width | Seconds [s] | A measure of the time between the beginning and end of the pulse, typically based on the full width half maximum (FWHM) of the pulse shape. Also called pulse duration. | |||
Repetition Rate | frep | Hertz [Hz] | The frequency with which pulses are emitted. Equal to the reciprocal of the period. |
Example Calculation:
Is it safe to use a detector with a specified maximum peak optical input power of 75 mW to measure the following pulsed laser emission?
The energy per pulse:
seems low, but the peak pulse power is:
It is not safe to use the detector to measure this pulsed laser emission, since the peak power of the pulses is >5 orders of magnitude higher than the detector's maximum peak optical input power.
Thorlabs offers a wide selection of power and energy meter consoles and interfaces for operating our power and energy sensors. Key specifications of all of our power meter consoles and interfaces are presented below to help you decide which device is best for your application. We also offer self-contained wireless power meters and compact USB power meters.
When used with our C-series sensors, Thorlabs' power meter consoles and interfaces recognize the type of connected sensor and measure the current or voltage as appropriate. Our C-series sensors have responsivity calibration data stored in their connectors. The console will read out the responsivity value for the user-entered wavelength and calculate a power or energy reading.
The consoles and interfaces are also capable of providing a readout of the current or voltage delivered by the sensor. Select models also feature an analog output.
Item # | PM100A | PM100D | PM400 | PM5020 |
---|---|---|---|---|
(Click Photo to Enlarge) | ||||
Key Features | Analog Power Measurements | Digital Power and Energy Measurements | Digital Power and Energy Measurements, Touchscreen Control | Dual Channel |
Compatible Sensors | Photodiode and Thermal Power | Photodiode Power, Thermal Power, and Pyroelectric Energya | Photodiode Power, Thermal Power, Thermal Power and Position, and Pyroelectric Energya | Photodiode Power, Thermal Power, Thermal Power and Position, and Pyroelectric Energy |
Housing Dimensions (H x W x D) |
7.24" x 4.29" x 1.61" (184 mm x 109 mm x 41 mm) |
7.09" x 4.13" x 1.50" (180 mm x 105 mm x 38 mm) |
5.35" x 3.78" x 1.16" (136.0 mm x 96.0 mm x 29.5 mm) |
9.97" x 4.35" x 11.56" (253.2 mm x 110.6 mm x 293.6 mm) |
Channels | 1 | 2 | ||
External Temperature Sensor Input (Sensor not Included) | - | - | Readout and Record Temperature Over Time | Readout and Record Temperature Over Time |
External Humidity Sensor Input (Sensor not Included) | - | - | Readout and Record Humidity Over Time | Readout and Record Humidity Over Time |
Input/Output Ports | - | 4 GPIO, Programmable | 4 Configurable Digital I/O Channels | |
Shutter Control | - | - | - | Support for SH05R(/M) or SH1(/M) Optical Shutter with Interlock Input |
Fan Control | - | - | - | |
Source Spectral Correction | - | - | ||
Attenuation Correction | - | - | ||
External Trigger Input | - | - | - | |
Display | ||||
Type | Mechanical Needle and LCD Display with Digital Readout | 320 x 240 Pixel Backlit Graphical LCD Display | Protected Capacitive Touchscreen with Color Display | |
Dimensions | Digital: 1.9" x 0.5" (48.2 mm x 13.2 mm) Analog: 3.54" x 1.65" (90.0 mm x 42.0 mm) |
3.17" x 2.36" (81.4 mm x 61.0 mm) |
3.7" x 2.1" (95 mm x 54 mm) |
4.32" x 2.43" (109.7 mm x 61.6 mm) |
Refresh Rate | 20 Hz | 10 Hz (Numerical) 25 Hz (Analog Simulation) |
25 Hz | |
Measurement Viewsb | ||||
Numerical | ||||
Mechanical Analog Needle | - | - | - | |
Simulated Analog Needle | - | |||
Bar Graph | - | |||
Trend Graph | - | |||
Histogram | - | - | - | |
Statistics | ||||
Memory | ||||
Type | - | SD Card | NAND Flash | SD Card |
Size | - | 2 GB | 4 GB | 8 GB |
Power | ||||
Battery | LiPo 3.7 V 1300 mAh | LiPo 3.7 V 2600 mAh | - | |
External | 5 VDC via USB or Included AC Adapter | 5 VDC via USB | Line Voltage: 100 - 240 V |
Item # | PM101 | PM102 | PM103 | PM101A | PM102A | PM103A |
---|---|---|---|---|---|---|
(Click Photo to Enlarge) | ||||||
Operation Protocol | USB, RS232, UART, and Analog |
USB and Analog SMA | ||||
Sensor Compatibility | ||||||
Photodiode | - | - | ||||
Thermal Power | - | - | ||||
Thermal Position & Power | - | - | - | - | ||
Pyroelectric | - | - | - | - | ||
Item # | PM103E | PM101R | PM101U | PM102U | PM103U | PM100USB | |
---|---|---|---|---|---|---|---|
(Click Photo to Enlarge) | |||||||
Operation Protocol | Ethernet, RS232, and Analog | USB and RS232 |
USB Operation | USB | |||
Sensor Compatibility | |||||||
Photodiode | - | ||||||
Thermal Power | - | ||||||
Thermal Position & Power | - | - | - | - | |||
Pyroelectric | - | - | - | a | |||
This tab outlines the full selection of Thorlabs' power and energy sensors. Refer to the lower right table for power meter console and interface compatibility information.
In addition to the power and energy sensors listed below, Thorlabs also offers all-in-one, wireless, handheld power meters and compact USB power meter interfaces that contain either a photodiode or a thermal sensor, as well as power meter bundles that include a console, sensor head, and post mounting accessories.
Thorlabs offers four types of sensors:
Console Compatibility | ||||||||
---|---|---|---|---|---|---|---|---|
Console Item # | PM100A | PM100D | PM400 | PM5020 | PM101 Series |
PM102 Series |
PM103 Series |
PM100USB |
Photodiode Power | - | |||||||
Thermal Power | - | |||||||
Thermal Position | - | - | - | - | - | |||
Pyroelectric Energy | - | a | a | - | - | a |
There are two options for comparing the specifications of our Power and Energy Sensors. The expandable table below sorts our sensors by type (e.g., photodiode, thermal, or pyroelectric) and provides key specifications.
Alternatively, the selection guide graphic further below arranges our entire selection of photodiode and thermal power sensors by wavelength (left) or optical power range (right). Each box contains the item # and specified range of the sensor. These graphs allow for easy identification of the sensor heads available for a specific wavelength or power range.
Photodiode Power Sensors |
---|
Thermal Power Sensors |
---|
Thermal Position & Power Sensors |
---|
Pyroelectric Energy Sensors |
---|
Kit Item # | PM120VA |
---|---|
Click Image to Enlarge | |
Included Console Item # |
PM100A |
Display | Analog Needle with 132 x 32 Pixel LCD |
Connectivity | USB 2.0 Connectivity |
Console Sensor Compatibility | All C-Series Photodiode and Thermal Power Sensors |
Post Assembly Threading | Imperial |
Mounting Base Compatibility | Imperial |
Included Sensor | S120VC |
---|---|
Wavelength Range | 200 - 1100 nm |
Power Range | 50 nW - 50 mW |
Resolution | 1 nW |
Detector Type | Si Photodiode |
Aperture | Ø9.5 mm |
Spec Sheet |
This kit includes our PM100A console, an S120VC photodiode power sensor, and a post assembly, consisting of a BA2 base, PH2 post holder, and TR2 Ø1/2" post. This is a general-purpose kit for low-power lasers (50 nW - 50 mW) within the visible and NIR regions. Surrounding the sensor's active area is a fluorescing alignment disk, which absorbs light from 200 - 525 nm. Many of our laser diodes and HeNe lasers are suitable for use with this power meter kit.
Thorlabs offers a recalibration service for this power and energy meter kit, which can be ordered using Item # CAL-UVPD below. Enter only the Part # and Serial # of the sensor that requires recalibration and include the corresponding console for recalibration during shipment.
We recommend recalibrating your sensor and console as a pair; however, if you would like to recalibrate only your console, use Item # CAL-PM1 below.
Part Number | Description | Price | Availability |
---|---|---|---|
PM120VA | Analog Power Console, Si Sensor, 200 nm - 1100 nm, 50 nW - 50 mW | $1,609.07 | 3-5 Days |
Kit Item # | PM120D | PM400K1 |
---|---|---|
Click Image to Enlarge | ||
Included Console Item # | PM100D | PM400 |
Display | 4" Backlit Digital Display, 320 x 240 Pixel Resolution |
4.3" Capacitive Color Touchscreen, WQVGA Resolution |
Connectivity | USB 2.0 Connectivity | |
Console Sensor Compatibility |
All C-Series Photodiode and Thermal Power Sensors as Well as All Pyroelectric Energy Sensors |
|
Post Assembly Threading | Imperial | |
Mounting Base Compatibility | Imperial |
Included Sensor | S120C |
---|---|
Wavelength Range | 400 - 1100 nm |
Power Range | 50 nW - 50 mW |
Resolution | 1 nW |
Detector Type | Si Photodiode |
Aperture | Ø9.5 mm |
Spec Sheet |
Each kit includes our PM100D or PM400 power meter console, a S120C photodiode sensor, and a post assembly, consisting of a BA2 base, PH2 post holder, and TR2 Ø1/2" post. This is a general purpose kit for low power lasers (50 nW - 50 mW) within the visible and NIR. Surrounding the sensor's active area is a fluorescing alignment disk, which absorbs light from 400 - 640 nm and 800 - 1700 nm. Many of our laser diodes and HeNe lasers are suitable for use with this power meter kit.
Thorlabs offers a recalibration service for these power and energy meter kits, which can be ordered using Item # CAL-PD below. Enter only the Part # and Serial # of the sensor that requires recalibration and include the corresponding console for recalibration during shipment.
We recommend recalibrating your sensor and console as a pair; however, if you would like to recalibrate only your console, use Item # CAL-PM1 below.
Part Number | Description | Price | Availability |
---|---|---|---|
PM120D | Digital Power & Energy Console, Si Sensor, 400 nm - 1100 nm, 50 nW - 50 mW | $1,626.58 | 3-5 Days |
PM400K1 | Touchscreen Digital Power & Energy Console, Si Sensor, 400 - 1100 nm, 50 nW - 50 mW | $1,939.58 | 3-5 Days |
Kit Item # | PM121D | PM400K2 |
---|---|---|
Click Image to Enlarge | ||
Included Console Item # | PM100D | PM400 |
Display | 4" Backlit Digital Display, 320 x 240 Pixel Resolution |
4.3" Capacitive Color Touchscreen, WQVGA Resolution |
Connectivity | USB 2.0 Connectivity | |
Console Sensor Compatibility |
All C-Series Photodiode and Thermal Power Sensors as Well as All Pyroelectric Energy Sensors |
|
Post Assembly Threading | Imperial | |
Mounting Base Compatibility | Imperial |
Included Sensor | S121C |
---|---|
Wavelength Range | 400 - 1100 nm |
Power Range | 500 nW - 500 mW |
Resolution | 10 nW |
Detector Type | Si Photodiode |
Aperture | Ø9.5 mm |
Spec Sheet |
Each kit includes our PM100D or PM400 console, a S121C photodiode sensor, and a post assembly, consisting of a BA2 base, PH2 post holder, and TR2 Ø1/2" post. This is a general purpose kit for low to medium power lasers (500 nW - 500 mW) within the visible and NIR spectrums (<1100 nm). It is similar to the S120C, which is included in the kit above, but an ND filter attenuates the light before the sensor. Surrounding the sensor's active area is a fluorescing alignment disk, which absorbs light from 400 - 640 nm and 800 - 1700 nm.
Thorlabs offers a recalibration service for these power and energy meter kits, which can be ordered using Item # CAL-PD below. Enter only the Part # and Serial # of the sensor that requires recalibration and include the corresponding console for recalibration during shipment.
We recommend recalibrating your sensor and console as a pair; however, if you would like to recalibrate only your console, use Item # CAL-PM1 below.
Part Number | Description | Price | Availability |
---|---|---|---|
PM121D | Digital Power & Energy Console, Si Sensor, 400 nm -1100 nm, 500 nW - 500 mW | $1,657.64 | 3-5 Days |
PM400K2 | Touchscreen Digital Power & Energy Console, Si Sensor, 400 nm - 1100 nm, 500 nW - 500 mW | $1,970.11 | 3-5 Days |
Kit Item # | PM130D | PM400K3 |
---|---|---|
Click Image to Enlarge | ||
Included Console Item # | PM100D | PM400 |
Display | 4" Backlit Digital Display, 320 x 240 Pixel Resolution |
4.3" Capacitive Color Touchscreen, WQVGA Resolution |
Connectivity | USB 2.0 Connectivity | |
Console Sensor Compatibility |
All C-Series Photodiode and Thermal Power Sensors as Well as All Pyroelectric Energy Sensors |
|
Post Assembly Threading | Imperial | |
Mounting Base Compatibility | Imperial |
Included Sensor | S130C |
---|---|
Wavelength Range | 400 - 1100 nm |
Power Range | 500 pW - 5 mW (Up to 500 mW with Filter)a |
Resolution | 100 pW |
Detector Type | Si Photodiode |
Aperture | Ø9.5 mm |
Spec Sheet |
Each kit includes our PM100D or PM400 console, a S130C photodiode power sensor, and a post assembly, consisting of a BA2 base, PH2 post holder, and TR2 Ø1/2" post. The kit's slim sensor head is ideal for use in tight spaces as it is only 0.2"
(5 mm) thick at its sensor. A sliding neutral density filter extends the power range that the sensor can be used to measure. With the filter out of the beam path, the power detection range is
500 pW to 5 mW. With the filter in the beam path, power detection from 50 nW to 500 mW is possible; however, power levels below 5 mW should be detected without the filter in the beam path for optimal results. The filter's position is automatically detected and accounted for by the power meter console.
Thorlabs offers a recalibration service for these power and energy meter kits, which can be ordered using Item # CAL-PD2 below. Enter only the Part # and Serial # of the sensor that requires recalibration and include the corresponding console for recalibration during shipment.
We recommend recalibrating your sensor and console as a pair; however, if you would like to recalibrate only your console, use Item # CAL-PM1 below.
Part Number | Description | Price | Availability |
---|---|---|---|
PM130D | Digital Power & Energy Console, Slim Si Sensor, 400 nm - 1100 nm, 500 pW - 500 mW | $1,863.11 | 3 Weeks |
PM400K3 | Touchscreen Digital Power & Energy Console, Slim Si Sensor, 400 nm - 1100 nm, 500 pW - 500 mW | $2,176.01 | 3-5 Days |
Kit Item # | PM122D | PM400K4 |
---|---|---|
Click Image to Enlarge | ||
Included Console Item # | PM100D | PM400 |
Display | 4" Backlit Digital Display, 320 x 240 Pixel Resolution |
4.3" Capacitive Color Touchscreen, WQVGA Resolution |
Connectivity | USB 2.0 Connectivity | |
Console Sensor Compatibility |
All C-Series Photodiode and Thermal Power Sensors as Well as All Pyroelectric Energy Sensors |
|
Post Assembly Threading | Imperial | |
Mounting Base Compatibility | Imperial |
Included Sensor | S122C |
---|---|
Wavelength Range | 700 - 1800 nm |
Power Range | 50 nW - 40 mW |
Resolution | 2 nW |
Detector Type | Ge Photodiode |
Aperture | Ø9.5 mm |
Spec Sheet |
Each kit includes our PM100D or PM400 console, a S122C photodiode sensor, and a post assembly, consisting of a BA2 base, PH2 post holder, and TR2 Ø1/2" post. This combination is ideal for customers working with wavelengths in the far red to NIR (700 - 1800 nm). Surrounding the sensor's active area is a fluorescing alignment disk, which absorbs light from 400 - 640 nm and 800 - 1700 nm.
Thorlabs offers a recalibration service for these power and energy meter kits, which can be ordered using Item # CAL-IRPD below. Enter only the Part # and Serial # of the sensor that requires recalibration and include the corresponding console for recalibration during shipment.
We recommend recalibrating your sensor and console as a pair; however, if you would like to recalibrate only your console, use Item # CAL-PM1 below.
Part Number | Description | Price | Availability |
---|---|---|---|
PM122D | Digital Power & Energy Console, Ge Sensor, 700 nm - 1800 nm, 50 nW - 40 mW | $1,981.89 | 3-5 Days |
PM400K4 | Touchscreen Digital Power & Energy Console, Ge Sensor, 700 nm - 1800 nm, 50 nW - 40 mW | $2,294.84 | 3 Weeks |
Kit Item # | PM125D | PM400K5 |
---|---|---|
Click Image to Enlarge | ||
Included Console Item # | PM100D | PM400 |
Display | 4" Backlit Digital Display, 320 x 240 Pixel Resolution |
4.3" Capacitive Color Touchscreen, WQVGA Resolution |
Connectivity | USB 2.0 Connectivity | |
Console Sensor Compatibility |
All C-Series Photodiode and Thermal Power Sensors as Well as All Pyroelectric Energy Sensors |
|
Post Assembly Threading | Imperial | |
Mounting Base Compatibility | Imperial |
Included Sensor | S425C |
---|---|
Wavelength Range | 0.19 - 20 µm |
Power Range | 2 mW - 10 W |
Resolution | 100 µW |
Detector Type | Thermal |
Aperture | Ø25.4 mm |
Spec Sheet |
Each kit includes our PM100D or PM400 power meter console, an S425C photodiode sensor, and a post assembly, consisting of a BA2 base, PH2 post holder, and TR2 Ø1/2" post. This is a general-purpose kit for customers working with higher powered lasers (up to 10 W) or longer wavelengths (up to 20 µm). The S425C thermal sensor has an exceptionally fast response time of 0.6 s.
Thorlabs offers a recalibration service for these power and energy meter kits, which can be ordered using Item # CAL-THPY below. Enter only the Part # and Serial # of the sensor that requires recalibration and include the corresponding console for recalibration during shipment.
We recommend recalibrating your sensor and console as a pair; however, if you would like to recalibrate only your console, use Item # CAL-PM1 below.
Part Number | Description | Price | Availability |
---|---|---|---|
PM125D | Digital Power & Energy Console, Thermal Sensor, 0.19 µm - 20 µm, 2 mW - 10 W | $2,192.77 | 3-5 Days |
PM400K5 | Touchscreen Digital Power & Energy Console, Thermal Sensor, 0.19 µm - 20 µm, 2 mW - 10 W | $2,505.61 | 3-5 Days |
Calibration Service Item # | Compatible Sensors |
---|---|
CAL-UVPD | S120VC |
CAL-PD | S116C, S120C, S121C, S170C, S171C, S140C, S142C, S142CL, S150C, S151C, PM16-120, PM16 |
CAL-UVPD2 | S130VC |
CAL-PD2 | S130C, PM16-130, PM160 |
CAL-NS | NS170C |
CAL-IRPD | S122C, S144C, S145C, S145CL, S146C, S154C, S155C, PM16-122, PM16-144 |
CAL-IRPD2 | S132C |
CAL-MIRPD | S148C, S180C |
Thorlabs offers recalibration services for our photodiode optical power sensors. To ensure accurate measurements, we recommend recalibrating the sensors annually. Recalibration of a single-channel power and/or energy meter console or interface is included with the recalibration of a sensor at no additional cost. If you wish to calibrate one or more sensors with a dual-channel console, each sensor and console calibration service will need to be purchased individually. For more details on these recalibration services, please click the Documents () icons below.
Refer to the table to the right for the appropriate calibration service Item # that corresponds to your power sensor.
Requesting a Calibration
Thorlabs provides two options for requesting a calibration:
Please Note: To ensure your item being returned for calibration is routed appropriately once it arrives at our facility, please do not ship it prior to being provided an RMA Number and return instructions by a member of our team.
Part Number | Description | Price | Availability |
---|---|---|---|
CAL-UVPD | Recalibration Service for S120VC UV-Extended Silicon Photodiode Power Sensor | $193.21 | Lead Time |
CAL-PD | Recalibration Service for Single-Power-Range Silicon Photodiode Power Sensors | $167.48 | Lead Time |
CAL-UVPD2 | Recalibration Service for S130VC Extended-UV Silicon Photodiode Power Sensor | $229.44 | Lead Time |
CAL-PD2 | Recalibration Service for Dual-Power-Range Silicon Photodiode Power Sensors | $194.83 | Lead Time |
CAL-NS | Recalibration Service for Second-Order Nonlinear Crystal with Silicon Photodiode Sensor | $335.00 | Lead Time |
CAL-IRPD | Recalibration Service for Single-Power-Range Germanium or InGaAs Photodiode Power Sensors | $188.88 | Lead Time |
CAL-IRPD2 | Recalibration Service for Dual-Power-Range Germanium or InGaAs Photodiode Power Sensors | $206.69 | Lead Time |
CAL-MIRPD | Recalibration Service for Extended InGaAs or MCT Photodiode Power Sensors | $337.37 | Lead Time |
Sensor Type | Sensor Item #s |
---|---|
Thermal Power | S175C, S302Ca, S305Ca, S310Ca, S314Ca,S322C, S350C, S370C, S401C, S405C, S415C, S425C, S425C-L, S470C, PM160T, PM160T-HP, PM16-401, PM16-405 |
Pyroelectric Energy | ES111C, ES120C, ES145C, ES220C, ES245C, ES308C, ES312C, ES408C, ES412C |
Thorlabs offers recalibration services for our Thermal Power and Pyroelectric Energy Sensors. To ensure accurate measurements, we recommend recalibrating the sensors annually. Recalibration of a single-channel power and/or energy meter console or interface is included with the recalibration of a sensor at no additional cost. If you wish to calibrate one or more sensors with a dual-channel console, each sensor and console calibration service will need to be purchased individually.
Please note that the CAL-THPY recalibration service cannot be used for our Thermal Position & Power Sensors; recalibration for these sensors can be requested by contacting Tech Support. The table to the upper right lists the sensors for which the CAL-THPY recalibration service is available.
Requesting a Calibration
Thorlabs provides two options for requesting a calibration:
Please Note: To ensure your item being returned for calibration is routed appropriately once it arrives at our facility, please do not ship it prior to being provided an RMA Number and return instructions by a member of our team. Pyroelectric energy sensors returned for recalibration or servicing must include the separate BNC to DB9 adapter, which contains the sensor EEPROM.
Part Number | Description | Price | Availability |
---|---|---|---|
CAL-THPY | Recalibration Service for Thermal Power and Pyroelectric Energy Sensors at 1064 nm | $212.62 | Lead Time |
Calibration Service Item # | Compatible Consoles & Interfaces |
---|---|
Single-Channel | |
CAL-PM1 | PM100D, PM100A, PM400, PM100USB, PM101 Series, PM102 Series, PM103 Series |
Dual-Channel | |
CAL-PM2 | PM5020, Previous-Generation PM320E |
These recalibration services are for the power and/or energy meter electronics of our consoles and interfaces. To ensure accurate measurements, we recommend recalibrating annually. Recalibration of a single-channel console or interface is included with these sensor recalibration services at no additional cost. If you wish to calibrate one or more sensors with a dual-channel console, each sensor and console calibration service will need to be purchased individually. For more details on these recalibration services, please click the Documents () icons below.
The table to the upper right lists the power and/or energy meter consoles and interfaces that can be calibrated using the CAL-PM1 and CAL-PM2 recalibration services.
Requesting a Calibration
Thorlabs provides two options for requesting a calibration:
Please Note: To ensure your item being returned for calibration is routed appropriately once it arrives at our facility, please do not ship it prior to being provided an RMA Number and return instructions by a member of our team.
Part Number | Description | Price | Availability |
---|---|---|---|
CAL-PM1 | Recalibration of Single-Channel Power and/or Energy Meter Electronics | $78.80 | Lead Time |
CAL-PM2 | Recalibration of Dual-Channel Power and Energy Meter Electronics | $210.12 | Lead Time |